Welcome to Our Community

Some features disabled for guests. Register Today.

XYZ Probe Plus Inversion Settings

Discussion in 'General Talk' started by Tim Bostock, Mar 8, 2021.

  1. Tim Bostock

    Builder

    Joined:
    Nov 28, 2020
    Messages:
    7
    Likes Received:
    2
    E987C8A9-FFDA-4C2F-9544-C90B66B45D3E.jpeg

    [EDIT: For info and to provide context for the references below, this thread was culled from a parallel one at: XYZ Probe Plus with VFDs and other ground-loop inducing components ]

    I seem to have a similar problem setting up my new OpenBuilds probe. This gives similar error message mentioned at the beginning of this thread by Peter Van Der Walt "The probe is not in the expected initial state before starting probe cycle, where G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered." - pic attached.

    My setup is xPro v5 and Router11. I have no VFD. I'm connecting via a MacBook running off battery power.

    I've been through all the above issues and fixes and crossed off each one as far as I'm aware. Obviously double checked wiring per docs:xyzprobe:wiringgeneric [OpenBuilds Documentation] and have correct separation between Earth (AC) and Ground (DC) with zero continuity.

    The probe LEDs light up correctly when the plate touches the router bit and also the clip wire. Any advice welcome :)
     
    #1 Tim Bostock, Mar 8, 2021
    Last edited: Mar 8, 2021
  2. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,877
    Likes Received:
    4,285
    Use the Troubleshooting tab to view the Probe status, then disconnect things until the problem clears - thats the best way to find where the short is coming from
     
  3. Tim Bostock

    Builder

    Joined:
    Nov 28, 2020
    Messages:
    7
    Likes Received:
    2
    Troubleshooting shows probe on (off when touching clip wire). I don't believe I have a short - the LEDs don't come on when the plate touches the router bit when clip not attached.
     
  4. Tim Bostock

    Builder

    Joined:
    Nov 28, 2020
    Messages:
    7
    Likes Received:
    2
    And btw, I also checked there's no continuity between end mill and GND. When I run the Probe routine (after confirming position) the spindle moves +22.5mm in X and Y before error code shows. Not sure if this is relevant, but everything I've tried so far yields the same result :(
     
  5. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    14,877
    Likes Received:
    4,285
    Thats opposite of normal. Check that $6=0 ?
     
  6. Tim Bostock

    Builder

    Joined:
    Nov 28, 2020
    Messages:
    7
    Likes Received:
    2
    Yes, it shows $6 as [Disable] / $6 = 0
     
  7. Tim Bostock

    Builder

    Joined:
    Nov 28, 2020
    Messages:
    7
    Likes Received:
    2
    It's now working. In settings I changed it to $6=Enable (it was $6=Disable) and saved changes to firmware. Your mentioning "that's opposite of normal" made me try this as I wasn't sure whether 0=Enable or Disable. Anyhow, that worked for me :)

    Thanks for the prompt!!

    Screenshot 2021-03-08 at 14.38.53.png
     
    Peter Van Der Walt likes this.
  8. sharmstr

    sharmstr OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 23, 2018
    Messages:
    2,059
    Likes Received:
    1,448
    Hey Tim - Looks like an old version of Control. Any reason why you havent updated? (btw - this question has nothing to do with your issue.)
     
    Peter Van Der Walt likes this.
  9. Tim Bostock

    Builder

    Joined:
    Nov 28, 2020
    Messages:
    7
    Likes Received:
    2
    Aha right - will check on that. Thanks for the tip! Just happy things now seem to be working
     
  10. Tim Bostock

    Builder

    Joined:
    Nov 28, 2020
    Messages:
    7
    Likes Received:
    2
    Hi - you were right - thanks for that. Am now updated to 290 (and the probe still works!).
     
    sharmstr likes this.